APC GVSUPS50K150HS
GVSUPS50K150HS Galaxy VS UPS 50kW 400V scalable to 150kW for external batteries, Start-up 5×8
Presentation
GVSUPS50K150HS APC Highly efficient and easy-to-deploy 50 kW scalable to 150 kW, 400V 3-phase UPS for external batteries that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5×8 start-up service.
Lead Time
- Usually ships within 2 weeks
Main Specifications
- Main Input Voltage: 400 V (3 phases)
- Other Input Voltage: 380 V, 415 V
- Main Output Voltage: 400 V (3 phases)
- Rated Power: 50 kW / 50 kVA (scalable to 150 kW / 150 kVA)
- Battery Type: External battery system, Li-Ion (Lithium-Ion), VRLA
- Provided Equipment: Dust filter, EcoStruxure IT ready (UPS), Installation guide, Integrated network management, Power modules ship installed, Start-up service
- Product Type: Uninterruptible Power Supply (UPS)
- Range of Product: Galaxy VS
Batteries & Runtime
- Battery Voltage: 480…576 V DC
- Maximum Current Discharge: 136 A
- Extended Runtime: 0
- Battery Power in VAh: 0 VAh runtime
General
- Bypass Voltage Tolerance: +/- 10%
- Redundant: No
Physical Specifications
- Colour: White
- Dimensions: 148.5 cm (H) x 52.1 mm (W) x 84.7 cm (D)
- Net Weight: 290 kg
- USB Compatible: No
Input Specifications
- Network Frequency: 40…70 Hz
- Input Voltage Limits: 340…460 V 400 V
- Maximum Input Current: 270 A
- Max Short Time Withstand Current: 65 kA
- Input Harmonic Distortion: Less than 3% for full load
- Load Power Factor: From 0.7 leading to 0.7 lagging without any derating
Output Specifications
- Maximum Configurable Power: 150 kW
- Output Frequency: 50 Hz sync to mains, 60 Hz sync to mains, 50 Hz +/- 0.1% for 50 Hz nominal unsynchronized, 60 Hz +/- 0.1% for 60 Hz nominal unsynchronized
- Crest Factor: 2.5
- Wave Type: Sine wave
- Output Voltage Tolerance: +/-1% after 50ms
- Output Harmonic Distortion: < 1% linear load and < 5% non-linear load
- Output Overload Operation: 10 minutes at 125% and 60 seconds at 150%
- Bypass Type: Built-in static bypass
Conformance
- Standards: EN/IEC 62040-1, EN/IEC 62040-2, FCC part 15 class A, IEC 60721-4-2 level 2M2, UL 1778 5th edition
Environmental Specifications
- Operating Temperature: 0…40 °C
- Relative Humidity: 0…95% non-condensing
- Operating Altitude: 0…3300 ft
- Storage Temperature: -25…55 °C
- Storage Relative Humidity: 10…80% non-condensing
- Acoustic Level: 68 dBA
- Heat Dissipation: 5804 Btu/h
- IP Protection: IP21
Communications & Management
- Control Panel: Touch screen LCD user interface
Packing Units
- Package Type: PCE
- Package Height: 168 cm
- Package Width: 99 cm
- Package Length: 64 cm
- Package Weight: 250 kg
- Number of Units in Package: 1