APC GVSUPS100K0B5HS
APC Galaxy VS UPS 100kW 400V for up to 5 internal 9Ah smart modular battery strings, Start-up 5×8
Presentation
Highly efficient and easy-to-deploy 100 kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. This UPS supports up to five smart modular high-capacity battery strings but is supplied without batteries, so you can easily customize the battery runtime. Includes 5×8 start-up service.
Lead Time
- Usually ships within 2 weeks
Main Specifications
- Main Input Voltage: 400 V (3 phases)
- Other Input Voltage: 380 V, 415 V
- Main Output Voltage: 400 V (3 phases)
- Other Output Voltage: 380 V, 415 V
- Rated Power: 100 kW / 100 kVA
- Battery Type: Internal modular battery, VRLA
- Provided Equipment: Dust filter, Installation manual, Integrated network management, Start-up service, EcoStruxure Ready
- Product Type: Uninterruptible Power Supply (UPS)
- Range of Product: Galaxy VS
Batteries & Runtime
- Battery Voltage: 480 V
- Discharge Battery Voltage: 384 V
- Maximum Current Discharge: 271 A
- Extended Runtime: 0
- Battery Power in VAh: 0 VAh runtime
General
- Redundant: No
Physical Specifications
- Colour: White
- Dimensions: 197 cm (H) x 55 cm (W) x 84.7 cm (D)
- Net Weight: 250 kg
- USB Compatible: No
Input Specifications
- Network Frequency: 40…70 Hz
- Input Voltage Limits: 340…460 V 400 V
- Maximum Input Current: 180 A
- Max Short Time Withstand Current: 65 kA
- Input Harmonic Distortion: Less than 3% for full load
- Load Power Factor: From 0.7 leading to 0.7 lagging without any derating
- Input Power Factor: 0.99 at full load
Output Specifications
- Maximum Configurable Power: 100 kW
- Harmonic Distortion: Less than 3%
- Output Frequency: 50 Hz sync to mains, 60 Hz sync to mains
- Crest Factor: 2.5
- Wave Type: Sine wave
- Output Voltage Tolerance: +/- 5% after 2ms, +/-1% after 50ms
- Output Harmonic Distortion: < 1% linear load and < 3% non-linear load
- Output Overload Operation: 10 minutes at 125% and 60 seconds at 150%
- Bypass Type: Built-in static bypass
Conformance
- Standards: IEC 62040-1-1, IEC 62040-2, OSHPD
Environmental Specifications
- Operating Temperature: 0…40 °C
- Relative Humidity: 0…95% non-condensing
- Operating Altitude: 0…3300 ft
- Storage Temperature: -15…40 °C
- Storage Relative Humidity: 10…80% non-condensing
- Storage Altitude: 0…3048 m
- Acoustic Level: 65 dBA
- Heat Dissipation: 12377 Btu/h
- IP Protection: IP20
Communications & Management
- Control Panel: Touch screen LCD user interface
Packing Units
- Package Type: PCE
- Package Height: 208.2 cm
- Package Width: 101 cm
- Package Length: 75.5 cm
- Package Weight: 250 kg