General
——–
Phase: Three Phase
Form Factor: Tower
UPS Topology: Online Double Conversion
Energy Saving Technology: ECO Mode Efficiency > 98%
Normal Mode Efficiency ( % ): 95%
Battery Mode Efficiency ( % ): 95%
Active PFC Compatibility: Yes
Parallel Expansion (Max. Units): 4
——
Input
——
Dual Power Inputs: Yes
Generator Compatibility: Yes
Nominal Input Voltage ( Vac ): Line to Neutral (L-N):220, 230, 240 Vac, Line to Line (L-L):380, 400, 415 Vac
Input Voltage Range ( Vac ): Line to Neutral (L-N): 132 ~ 276 Vac, Line to Line (L-L): 228 ~ 478 Vac
Configurable Voltage Range ( Vac ): 220 ~ 250 Vac
Line to Line (L-L): 380 ~ 435 Vac
Input Frequency ( Hz ): 50 ± 3, 60 ± 3
Input Frequency (Configurable) ( Hz ): 50 ± 1, 50 ± 5, 60 ± 1, 60 ± 5
Input Frequency Range ( Hz ): 40 ~ 70
Rated Input Current ( A ): 21
THDI (%): <3% (Linear Load)
Input Power Factor: 0.99
Overload Protection (Bypass): 125~130% Load for 10 min, 130~150% Load for 1 min, 150~400% Load for 1 sec, >400% Load Immediately
Input Connector Type: Hardwire Terminal Block
——-
Output
——-
Capacity (VA): 15000
Capacity (Watts): 13500
On Battery Waveform: Pure Sine Wave
Output Voltage Setting: Configurable
Output Frequency Setting: Configurable
Rated Output Voltage ( Vac ): Line to Neutral (L-N):220, 230, 240 Vac, Line to Line (L-L):380, 400, 415 Vac
Output Voltage Tolerance ( % ): Line Mode & Battery Mode: 1 %
Output Frequency ( Hz ± % ): Line Mode & Battery Mode: 50 ± 0.1, Line Mode & Battery Mode: 60 ± 0.1
Power Factor: 0.9
ECO Mode Voltage Tolerance: ± 10 %
Overload Protection: Internal Current Limiting, Circuit Breaker, Fuse
Overload Protection (Line Mode): 105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately
Overload Protection (Battery Mode): 105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately
Overload Protection (Bypass Mode): 125~130% Load for 10 min, 130~150% Load for 1 min, 150~400% Load for 1 sec, >400% Load Immediately
Crest Factor: 3 : 1
Harmonic Distortion (Linear Load): THD<1%
Harmonic Distortion (Non-linear Load): THD<5%
Internal Bypass: Automatic Bypass, Manual Bypass
Maintenance Bypass: Yes
Outlet Type: Hardwire Terminal Block x 1
Typical Transfer Time ( ms ): 0
——–
Battery
——–
Compatible Battery Types: VRLA, AGM, Gel, Wet, Lithium-ion
Recharge Power ( % ): Default 10% (Selectable from 1~20% x UPS Capacity)
Recharge Power Setting: Configurable
Smart Battery Management (SBM): Yes
User-replaceable: No
Battery Solution: Extended Battery
Battery Voltage ( V ): ±240 (480)
Compatible Extended Battery Cabinet (EBC): SMBF17, SMBF20, SMBF26, SMBF33, SMBF40, SMBF65, BCA100N125, BCA12N63, BCA20N125, BCA40N125
External Battery Quantity: 12V x 40(Default)/32/34/36/38/42/44pcs (32/34pcs require UPS power de-rating)
—————————–
Surge Protection & Filtering
—————————–
EMI/RFI Filtration: Yes
—————————-
Management & Communications
—————————-
LCD Panel: Yes
LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log
LCD Setting & Control: Mode Setting, Input & Output, Battery Setting, Communication, Event & Log, Security Setting, Language
LED Indicators: Yes
Serial Port: RS232 x 1 + RS485 x 1 + Dry Contact x1
Dry Contact (with Relay): Yes
Emergency Power Off (EPO) Port: Yes
Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery
Power Management Software: PowerPanel Business (Recommended)
SNMP/HTTP Remote Monitoring: Yes – with optional RMCARD205
———
Physical
———
Enclosure Construction: Metal
Color: Black
Ingress Protection: IP20
—————————-
Physical Size – UPS Module
—————————-
Dimensions (WxHxD) (mm.): 250 x 530 x 660
Weight (kg.): 31
——————–
Shipping Dimensions
——————–
Dimensions (WxHxD) (mm.): 390 x 630 x 795
Weight (kg.): 35
————–
Environmental
————–
Operating Temperature (°C): 0 ~ 40
Operating Relative Humidity (Non-condensing) ( % ): 0 ~ 95
Operating Elevation ( feet/meters ): ≤1000, Load Derated 1% per 100m from 1000m and 2000m
Storage Temperature (°C): -40 ~ 70
Storage Relative Humidity (Non-condensing) ( % ): 0 ~ 95
—————
Certifications
—————
Certifications: CE, IEC62040-1, IEC62040-2