CyberPower OL3000RTXL2U

OL3000RTXL2U OL series RT 3000VA/2700W,PF0.9

2-yrs onsite with battery

***กรณีสั่งซื้อกับทางเราสามารถแจ้งเคลมผ่านกับเราได้เลย

ซื้อทางไลน์

ติดต่อเราเพื่อสั่งซื้อ สอบถาม หรือขอใบเสนอราคา
โทร : 02-140-0892
มือถือ : 089-314-3423
Line ID : @plantdigi
Email : info@plantdigi.com

SKU: OL3000RTXL2U Categories: , , Tag:
แชร์หน้านี้:

CyberPower OL3000RTXL2U

OL series RT 3000VA/2700W,PF0.9

Smart App Online UPS ENTERPRISE ONLINE UPS TO SAFEGUARD DATA CENTER The high performance online double-conversion UPS designed with zero transfer time for IT equipment

——–
General
——–
Phase: Single Phase
Form Factor: Rackmount, Tower
UPS Topology: Online Double Conversion
Energy Saving Technology: ECO Mode Efficiency > 95%
Energy Star Qualified: Yes
Active PFC Compatibility: Yes
——
Input
——
Generator Compatibility: Yes
Nominal Input Voltage ( Vac ): 100, 110, 115, 120, 125
Input Voltage Range ( Vac ): 100 ~ 125
Adjustable Voltage Range ( Vac ): 0~60% Load for 60 ~ 69 Vac, 0~70% Load for 70 ~ 79 Vac, 0~80% Load for 80 ~ 89 Vac, 0~90% Load for 90 ~ 95 Vac, 0~100% Load for 96 ~ 150 Vac
Input Frequency ( Hz ): 50 ± 10, 60 ± 10
Input Frequency Detection: Auto-sensing
Rated Input Current ( A ): 24
Input Power Factor: 0.99
Input Connector Type: NEMA L5-30P
Plug Style: Straight
Power Cord Length (ft.): 10
Power Cord Length (m.): 3
——-
Output
——-
Capacity (VA): 3000
Capacity (Watts): 2700
On Battery Waveform: Pure Sine Wave
On Battery Voltage(s) ( Vac ): 100 ± 2 %, 110 ± 2 %, 115 ± 2 %, 120 ± 2 %, 125 ± 2 %
Output Voltage Setting: Configurable
On Battery Frequency ( Hz ): 50 ± 0.5%, 60 ± 0.5%
Output Frequency Setting: Configurable
Power Factor: 0.9
ECO Mode Voltage Tolerance: ± 10 %, ± 15 %
Overload Protection: Internal Current Limiting, Circuit Breaker
Overload Protection (Line Mode): 105~125% Load for 1 min, 125~150% Load for 10 sec
Overload Protection (Battery Mode): 105~130% Load for 10 sec, 130~150% Load for 2 sec
Overload Protection (Bypass Mode): Circuit Breaker
Crest Factor: 3 : 1
Harmonic Distortion (Linear Load): THD<3%
Harmonic Distortion (Non-linear Load): THD<5%
Internal Bypass: Automatic Bypass, Manual Bypass
Outlet(s) – Total: 7
Outlet Type: NEMA 5-20R x 6, NEMA L5-30R x 1
Outlet(s) – Battery & Surge Protected: 7
Outlet(s) – Critical Load (CL): 3
Outlet(s) – Non-Critical Load (NCL): 4
Typical Transfer Time ( ms ): 0
——–
Battery
——–
Runtime at Half Load ( min ): 9
Runtime at Full Load ( min ): 3
Typical Recharge Time ( Hours ): 4
Start On Battery: Yes
Smart Battery Management (SBM): Yes
User-replaceable: Yes – Qualified Personnel Only
Hot-swappable: Yes
Battery Type: Sealed Lead-acid
Replacement Battery Pack (RBP): RBP0076, RB1290X6A
Replacement Battery Pack (RBP) Quantity ( pcs ): 1
Battery Quantity (Each RBP) ( pcs ): 6
Battery Voltage (Each RBP) ( V ): 72
Compatible Extended Battery Module (EBM): BP72V60ART2U (Built-in Charger)
Max. EBM Quantity ( pcs ): 10
—————————–
Surge Protection & Filtering
—————————–
Surge Suppression ( Joules ): 1335
EMI/RFI Filtration: Yes
Phone/Network Protection RJ11/RJ45 (Combo): 1-in, 1-out
—————————-
Management & Communications
—————————-
LCD Panel: Yes
LCD Types: Detachable LCD Panel
LCD Orientation: Rotatable LCD – via Setting
LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log
LCD Setting & Control: Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning, Communication, Event & Log, Security Setting, Language
LED Indicators: Power On, Line Mode, Battery Mode, Bypass Mode, Battery Capacity, Low Battery, Overload, UPS Fault, Wiring Fault, Replace Battery
HID Compliant USB Port(s): 1
Dry Contact (with Relay): Yes
Emergency Power Off (EPO) Port: Yes
Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery
Management Cable ( pcs ): USB Cable x1, Serial Cable x1, Phone Line x1
Power Management Software: PowerPanel Business (Recommended)
PowerPanel Cloud Service: Yes – 90 Days Free Trial with PowerPanel Personal/Business
———
Physical
———
Enclosure Construction: Metal
Color: Black
Rackmount Rail: Yes
Rackmount Ears: Yes
————————-
Physical Size – UPS Module
————————-
Dimensions (WxHxD) (in.): 17 x 3.5 x 23.62
Dimensions (WxHxD) (mm.): 433 x 88 x 600
Weight (lbs.): 68.2
Weight (kg.): 31
Installed Rack Height ( U ): 2
——————–
Shipping Dimensions
——————–
Dimensions (WxHxD) (in.): 22.2 x 9.5 x 34.6
Dimensions (WxHxD) (mm.): 564 x 240 x 880
Weight (lbs.): 86.9
Weight (kg.): 39.5
————–
Environmental
————–
Operating Temperature (°F): 32 ~ 104
Operating Temperature (°C): 0 ~ 40
Operating Relative Humidity (Non-condensing) ( % ): 0 ~ 90
Operating Elevation ( feet/meters ): 0-9,843 feet (0-3,000 meters)
Storage Temperature (°F): 5 ~ 113
Storage Temperature (°C): -15 ~ 45
Storage Relative Humidity (Non-condensing) ( % ): 0 ~ 95
Storage Elevation ( feet/meters ): 0-49,213 feet (0-15,000 meters)
Online Thermal Dissipation ( BTU/hr ): 1139
Audible Noise at 1.0M from Surface of Unit: 38~55 dBA (0~100 % load)
————–
Certifications
————–
Certifications: FCC Class A, UL, BSMI, VCCI
RoHS: Yes
———
WARRANTY
———
Product Warranty Period (Year): 2

Battery Warranty Period (Year): 2

Shopping Cart
Scroll to Top